2.1
Designing the panels
2
-5
Installing a heat exchanger
It is the responsibility of the customer to prepare and install together an enclosure and a heat
exchanger. The internal fan must be mounted at an uppermost location so as to force the
internal air down. The external fan must be mounted at a lowermost location so as to force
the external air up.
Fig. 2.1 shows an example installation of a heat exchanger.
Fig. 2.1 Example installation of a heat exchanger
• Always install a heat exchanger.
Otherwise damage could result.
MANDATORY
Flow of external air
Flow of internal air
Enclosure
(Up)
(Down)
Heat exchanger